Thermal Relays Test System at Arctic |
Purpose
The software application developed for this project controls the thermal relays testing equipment and provides the user interface, records management and reporting system.
Technical Details
- 1 monitoring station point
- 27 surveillance parameters (25 binaries, 2 temperatures)
- equipment:
- Agilent Data Acquisition and Switch Unit, 20 Channel Multiplexer module and 20 Channel Switch module (34970A, 34901A, 34903A)
- Agilent Electronic Load 6063B
- Votsch stove
- USB GPIB interface enabled computer
- color inkjet printer
IT characteristics
- the software application conducts current and temperature tests
- the test results are organized in tables where values are distinguished by the belonging interval
- results statistics and graphics
- printable results report
- results are saved for later view
- the application was developed using LabVIEW